MCP01 automatic capsule counter counting machine
Product Feature
1. It can spot a variety of shapes of tablets and capsules, the maximum speed can reach 500 per minute (or two)
2. Points accuracy rate of up to 100%
3. The cleaning and maintenance of the product is simple and convenient
4. Drugs should not be in direct contact with
5. Small size, suitable for all kinds of work space
6. Equipped with a funnel box drawers, can be directly bottling or packaging
DETAIL DRAWING
Technical parameters
Voltage |
220V/110V |
Power |
100W |
Capacity |
500 pcs/min |
Weight |
8.5KG |
Operation steps
1. Place machine on a LEVEL surface.
2. Turn machine ON.
3. Close gate by turning the adjustment knob clockwise. Be certain drawers are completely closed.
4. Pour tablets on turntable. DO NOT overload.
5. Select Mode on Key Pad:
Single Mode(SGL)
Use this mode to count a pre-determined number of tablets and dispense intothe top drawer.
When the top drawer is removed, excess tablets on the turntable will drop into the bottom drawer.
Multiple Mode(MULTI)
Use this mode for counting multiple quantities from the same batch. When the top drawer containing the pre-determined count is removed, excess tablets will remain on the turntable.
Insertcollection drawerand Press START to perform additional counts. To clear turntable after last count, leave top drawer out and press CLEAR/INVENTORY/START.
Inventory Mode(INV)
Use this mode to count an entire amount of tablets. The HSPI will count up to 1,000 and restart at 1.(Do not set quantity)
6. (Except in INVENTORY Mode) PressCLEAR and set quantity using the Key Pad.
7. Press START.
Turn Gate Adjustment Knob slowly counterclockwise, just wide enough for tablets to pass through in single file. Adjust Separator Tab on track arm UP for large 'tablets and all capsules; DOWN for smaller, flat sizes to prevent overriding.